We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Expression Gauge.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Expression Gauge - List of Manufacturers, Suppliers, Companies and Products

Expression Gauge Product List

1~11 item / All 11 items

Displayed results

[Case Study of Limit Gauge Production] for Internal Diameter of Angled Holes

Check for hole penetration from the side! Determine whether the inclined surface of the flange contacts the product.

We would like to introduce a case study of our limit-type gauge "for angled hole inner diameter." To confirm the hole's penetration from the through side, an inclined ring is attached to the flange part. The judgment is made based on whether the inclined surface of the flange contacts the product. The reference measurement dimensions are φ7+0.4/-0.15. Please feel free to contact us if you have any requests. 【Case Overview】 ■ Hole penetration confirmation from the through side ■ Inclined ring attached to the flange part ■ Judgment based on whether the inclined surface of the flange contacts the product ■ Reference measurement dimensions: φ7+0.4/-0.15 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Inspection fixture

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Limit Gauge Production] For Serration Groove Spacing

Measuring the distance (angle) of the serration groove of the TM case! Production example for positional accuracy.

We would like to introduce a production example of our limit-type gauge for measuring the "serration groove distance." This gauge measures the serration groove distance (angle) of the TM case. The reference measurement dimension is a positional accuracy of 0.2. Please feel free to contact us if you have any requests. 【Case Overview】 ■ Gauge for measuring the serration groove distance (angle) of the TM case ■ Reference measurement dimension: positional accuracy of 0.2 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Inspection fixture

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge for internal diameter

The reference measurement dimensions are φ5.9±0.15! If it fits on the through side, it's OK; if it fits on the stop side, it's NG.

We would like to introduce the "limit gauge for inner diameter" that we handle. This product is the most orthodox type of limit gauge, where it is acceptable if the go side fits, but not acceptable if the no-go side fits. Please feel free to consult us when you need assistance. 【Features】 ■Reference measurement dimension: φ5.9±0.15 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge for screw holes

A ring with a step has been installed to check the hole depth on the side!

We would like to introduce our "Limit Gauges for Screw Holes." A stepped ring is attached to check the hole depth on the through side. The step can be visually inspected or touched with a finger for judgment. Please feel free to consult us when you need assistance. 【Features】 ■ Reference measurement dimensions: M8×1.25, hole depth 20 +1.0/0 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge for direct spacing of 2 holes

Fix two pins to the plate! Introducing our products for positional accuracy that we have prepared.

We would like to introduce our "limit gauge for 2-hole direct spacing" that we handle. This product is for positional measurement, and the two pins are fixed to the plate. The reference measurement dimension is 184.05±0.05. Please feel free to consult us when you need assistance. 【Features】 ■ Reference measurement dimension: 184.05±0.05 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge <pitch gauge>

Reference measurement dimension is positional accuracy φ0.28! It combines the direct distance between the primary and secondary reference holes and the measurement of the hole positions of the primary and secondary references.

We handle "Limit Gauges <Pitch Gauges>" for positional accuracy. By swapping out pins, it can be used for both measuring the direct distance between primary and secondary reference holes and measuring the positions of the primary and secondary reference holes. The reference measurement dimension is positional accuracy φ0.28. Please feel free to consult us when you need assistance. 【Features】 ■ Reference measurement dimension: Positional accuracy φ0.28 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge for serration groove spacing.

Measuring the serration groove spacing of the TM case! Introducing products for positional accuracy.

We would like to introduce our "Limit Gauge for Serration Groove Distance" that we handle. This gauge measures the serration groove distance (angle) of the TM case, with a reference measurement dimension of positional accuracy 0.2. Please feel free to consult us when you need it. 【Features】 ■ Reference measurement dimension: Positional accuracy 0.2 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Limit Gauge Production] For Screw Holes

Judging the step difference by visual inspection or touch! An example of installing a ring with a step difference.

We would like to introduce a case study of the limit gauge "for screw holes" that we handle. To check the hole depth on the through side, a stepped ring is attached, and the step can be visually inspected or touched with a finger for judgment. The reference measurement dimensions are M8×1.25, with a hole depth of 20+1.0/0. Please feel free to contact us if you have any requests. 【Case Overview】 ■ Check hole depth on the through side ■ Attach a stepped ring ■ Reference measurement dimensions ・M8×1.25 ・Hole depth 20+1.0/0 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Inspection fixture

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Example of Limit Gauge Production] For 2-Hole Direct Spacing

Two pins are fixed to the plate! The reference measurement dimension for positioning is 184.05±0.05.

We would like to introduce a production example of our limit gauge "for the distance between two holes." The two pins are fixed to the plate, and the reference measurement dimension is 184.05±0.05. Please feel free to contact us if you have any requests. 【Case Overview】 ■ Two pins fixed to the plate ■ Reference measurement dimension: 184.05±0.05 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Inspection fixture

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Limit Gauges] Pitch Gauge

Introducing a case that combines the measurement of the direct distance between the primary and secondary reference holes and the positions of the primary and secondary reference holes.

We would like to introduce a case study of the limit-type gauge "Pitch Gauge" that we handle. By swapping the pins, it serves a dual purpose of measuring the direct distance between the primary and secondary reference holes and the positions of the primary and secondary reference holes. The reference measurement dimension is positional accuracy φ0.28. Please feel free to contact us if you have any requests. 【Case Overview】 ■ By swapping the pins, it serves a dual purpose of measuring the direct distance between the primary and secondary reference holes and the positions of the primary and secondary reference holes. ■ Reference measurement dimension: positional accuracy φ0.28 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Inspection fixture

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Limit gauge for inner diameter of angled holes.

The reference measurement dimensions are φ7 +0.4/-0.15! A sloped ring is attached to the flange part.

We would like to introduce our "Limit Gauge for the Inner Diameter of Angled Holes." To confirm the through-hole on the pass side, an inclined ring is attached to the flange part. The judgment is made based on whether the inclined surface of the flange comes into contact with the product. Please feel free to consult us when you need assistance. 【Features】 ■ Reference measurement dimensions: φ7 +0.4/-0.15 *For more details, please refer to the related links or feel free to contact us.

  • Other work tools
  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration